01E Acknowledgement signal for water level not received within time
allowed.
02E Door status acknowledgement signal not received during program operation.
03E Door lock acknowledgement signal not received within time
allowed.
04E Temperature sensing device indicates temperature below -5°C
(continuity fault)
05E Temperature sensing indicates temperature above 98°C (short-
circuit).
06E Water level signal above parameter set, on program start-up
07E Water level signal above parameter set for safety, during program.
08E Increase in water temperature is below parameter set.
10E. Water level signal is above parameter set (10 scale units) after
water discharge.
12E. The program control unit cannot read the program EPROM.
13E. The program control unit receives no response from the motor
control unit.
14E. Water level system not calibrated.
17E. Door status acknowledgement signal not received, although door
lock acknowledgement signal has been received.
18E. Only with CALCAD 4400. Start not allowed because full payment
has not been made for that program, or the booking time is too
short to allow completion of the wash program selected.
19E. Communications between the CALCAD 4400 and the program
control unit board interrupted.
20E. Motor control unit has not received signal for lock
acknowledgement, during program.
21E. Microprocessor error (Configuration register).
31E. Motor control overheated.
32E. The motor controller indicates the thermal protector of the motor
has triggered . (Only W355H).
33E. The motor controller receives a start command from the
programme unit without receiving an interlock ACK (”Door locked”
signal). (Only W355H).
35E. Motor control unit indicating short-circuit between motor winding
outputs.
36E. Motor control unit indicating fault/error in receiving circuitry for lock
acknowledgement signal.
37E. Motor control unit indicating DC voltage level too low.
38E. Motor control unit indicating DC voltage level too high.
45E. Pulses from speed sensor missing. (Only W355H).
Mer Hjälp